3.5mm - Archoverseas https://archoverseas.com My WordPress Blog Sat, 22 Feb 2025 09:45:08 +0000 en-US hourly 1 https://wordpress.org/?v=6.8.1 https://archoverseas.com/wp-content/uploads/2024/11/cropped-Untitled-design-32x32.png 3.5mm - Archoverseas https://archoverseas.com 32 32 Locking Plate Calcaneal 3.5mm, Right/Left https://archoverseas.com/product/locking-plate-calcaneal-3-5mm-right-left-2/?utm_source=rss&utm_medium=rss&utm_campaign=locking-plate-calcaneal-3-5mm-right-left-2 Sat, 22 Feb 2025 07:05:46 +0000 https://archoverseas.com/?post_type=product&p=18770 Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP860113 LCP860115 AX-013R AX-015R Right Right 13H 15H LCP860013 LCP860015 AX-013L AX-015L Left Left 13H 15H 3.5 mm Locking Plate Calcaneal, Right/Left Specification Plates has 13 and 15 holes, Versatile 15 locking holes address multiple fracture patterns. Plates available […]

The post Locking Plate Calcaneal 3.5mm, Right/Left first appeared on Archoverseas.

]]>
Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP860113

LCP860115 AX-013R

AX-015R Right

Right 13H

15H LCP860013

LCP860015 AX-013L

AX-015L Left

Left 13H

15H

3.5 mm Locking Plate Calcaneal, Right/Left Specification

  • Plates has 13 and 15 holes, Versatile 15 locking holes address multiple fracture patterns.
  • Plates available for Left and Right both direction.
  • Plates available in two length, 69 mm and 76 mm.
  • Bendable tabs provide support for the anterior process and plantar fragments.
  • Angled and ascending holes buttress the sustentaculum and provide better support of the calcaneotalar articular surface Lateral application.
  • Locking screws provide standard bicortical and/or unicortical fixation.
  • Threaded locking holes offer a fixed-angle construct to buttress the articular surfaces of the calcaneus.
  • Permit multiple points of fixation to buttress small fragments.
  • Accept standard 2.7 mm and 3.5 mm cortical screws as alternatives to, or in conjunction with, 3.5 mm locking screws.
  • 3.5 mm Locking Plate Calcaneal, Right/Left allow implant placement to address the individual fracture pattern.
  • Choice of different lengths of plate eliminates the need to cut plates.
  • Pre-contoured plate to match anatomical shape.
  • Available in both Titanium and Stainless steel.
  • locking plate increases construct stability, decreases risk of screw back-out and subsequent loss of reduction. It also reduces the need for precise anatomic plate contouring and minimizes the risk of stripped screw holes.
  • A complete Instruments Set is available for Calcaneal Plates. General Instruments are available for this plate such as Plate Bending Press, Plate Holding Forceps, Plate Bending Pliers, Bone Holding Forceps, Bone Elevators, Bone Cutter, Bone Nibbler, Depth Gauge, Sleeve, Screw Driver, Trocar Sleeve etc.

3.5 mm Locking Plate Calcaneal, Right/Left Uses

  • 3.5 mm Locking Plate Calcaneal, Right/Left address complex fractures of the calcaneus.
  • 3.5 mm Locking Plate Calcaneal, Right/Left are indicated for fractures and osteotomies of the calcaneus including, but not limited to, extra-articular, intra- articular, joint depression, tongue type, and severely comminuted fractures.

3.5 mm Locking Plate Calcaneal, Right/Left Contraindications

Contraindications may be qualified or total, and need to be taken into consideration when evaluating the prognosis in each case. Alternative management techniques may need to be considered under the following conditions:

  • Acute or chronic infections, either local or systemic.
  • Local or systemic accurate or chronic inflammation.
  • Serve muscular, nervous or vascular disease endangering the affected area.
  • Defective bone structures, which would impede adequate anchoring of the implant.
  • All associated diseases which could endanger the function and success of the implant.

Warnings and Precautionary for 3.5 mm Locking Plate Calcaneal, Right/Left

Before using 3.5 mm Locking Plate Calcaneal, Right/Left, the surgeon and ancillary staff should study the safety information in these instructions, as well as any product-specific information in the product description, surgical procedures and/or brochures.

Plates are made from medical grade materials and are designed, constructed and produced with utmost care. These quality assure best working results provided they are used in the proper manner. Therefore, the following instructions for use and safety recommendations must be observed.

Improper use of Plates can lead to damage to the tissue, premature wear, destruction of the instruments and injury to the operator, patients or other persons.

It is vital for the operating surgeon to take an active role in the medical management of their patients. The surgeon should thoroughly understand all aspects of the surgical procedure and instruments including their limitations. Care in appropriate selection and proper use of surgical instruments is the responsibility of the surgeon and the surgical team. Adequate surgical training should be completed before use of 3.5 mm Locking Plate Calcaneal, Right/Left.

Factors which could impair the success of the operation:

  • Allergies to implanted materials.
  • Localized bone tumours.
  • Osteoporosis or osteomalacia.
  • System disease and metabolic disturbances.
  • Alcohol and drug abuse.
  • Physical activities involving excessive shocks, whereby the implant is exposed to blows and/or excessive loading.
  • Patients who are mentally unable to understand and comply with the doctor’s instructions.
  • Poor general health.

Possible Adverse Effects

The following adverse effects are the most common resulting from implantation:

  • Loosening of the 3.5 mm Locking Plate Calcaneal, Right/Left, which may result from cyclic loading of the fixation site and/or tissue reaction of the implant.
  • Early and late infection.
  • Further bone fracture resulting from unusual stress or weakened bone substance.
  • Temporary or chronic neural damage resulting from pressure or hematomata.
  • Wound hematomas and delayed wound healing.
  • Vascular disease including venal thrombosis, pulmonary embolism and cardiac arrest.
  • Heterotopic ossification.
  • Pain and discomfort due to presence of the Implants.
  • Mechanical failure of the implant, including bending, loosening or breakage.
  • Migration of implant resulting in injury.

Preoperative Planning for 3.5 mm Locking Calcaneal Plates

The operating planning is carried out following a thorough clinical evaluation of the patient, Also, x-rays must be taken to allow a clear indication of the bony anatomy and associated deformities. At the time of the operation, the corresponding implantation instruments in addition to a complete set of 3.5 mm Locking Plate Calcaneal, Right/Left must be available.

The clinician should discuss with the patient the possible risks and complications associated with the use of Implants. It is important to determine pre-operatively whether the patient is allergic to any of the implant materials. Also, the patient needs to be informed that the performance of the device cannot be guaranteed as complications can affect the life expectancy of the device.

3.5 mm Locking Plate Calcaneal, Right/Left Precautions

  • Confirm functionality of instruments and check for wear during reprocessing. Replace worn or damaged instruments prior to use.
  • It is recommended to use the instruments identified for this screw.
  • Handle devices with care and dispose worn bone cutting instruments in a sharps container.
  • Always irrigate and apply suction for removal of debris potentially generated during implantation or removal.

3.5 mm Locking Plate Calcaneal, Right/Left Warnings

  • 3.5 mm Locking Plate Calcaneal, Right/Left can break during use (when subjected to excessive forces). While the surgeon must make the final decision on removal of the broken part based on associated risk in doing so, we recommend that whenever possible and practical for the individual patient, the broken part should be removed. Be aware that implants are not as strong as native bone. Implants subjected to substantial loads may fail.
  • Instruments, screws and cut plates may have sharp edges or moving joints that may pinch or tear user’s glove or skin.
  • Take care to remove all fragments that are not fixated during the surgery.
  • While the surgeon must make the final decision on implant removal, we recommend that whenever possible and practical for the individual patient, fixation devices should be removed once their service as an aid to healing is accomplished. Implant removal should be followed by adequate post-operative management to avoid refracture.

3.5 mm Locking Plate Calcaneal, Right/Left General Adverse Events

As with all major surgical procedures, risks, side effects and adverse events can occur. While many possible reactions may occur, some of the most common include: Problems resulting from anesthesia and patient positioning (e.g. nausea, vomiting, dental injuries, neurological impairments, etc.), thrombosis, embolism, infection, nerve and/or tooth root damage or injury of other critical structures including blood vessels, excessive bleeding, damage to soft tissues incl. swelling, abnormal scar formation, functional impairment of the musculoskeletal system, pain, discomfort or abnormal sensation due to the presence of the device, allergy or hypersensitivity reactions, side effects associated with hardware prominence, loosening, bending, or breakage of the device, mal-union, non-union or delayed union which may lead to breakage of the implant, reoperation.

The post Locking Plate Calcaneal 3.5mm, Right/Left first appeared on Archoverseas.

]]>
Locking Plate Metaphyseal 3.5mm https://archoverseas.com/product/locking-plate-metaphyseal-3-5mm/?utm_source=rss&utm_medium=rss&utm_campaign=locking-plate-metaphyseal-3-5mm Sat, 22 Feb 2025 07:05:46 +0000 https://archoverseas.com/?post_type=product&p=18771 3.5 mm Locking Plate Metaphyseal Specification Plates available holes are 6, 7, 8, 9, 10, 11 and 12. Plate has combi holes and round holes. Combi holes allow fixation with locking screws in the threaded section and cortex screws in the dynamic compression unit section for compression. The shaft holes accept 3.5 mm locking screws in the […]

The post Locking Plate Metaphyseal 3.5mm first appeared on Archoverseas.

]]>

3.5 mm Locking Plate Metaphyseal Specification

  • Plates available holes are 6, 7, 8, 9, 10, 11 and 12.
  • Plate has combi holes and round holes. Combi holes allow fixation with locking screws in the threaded section and cortex screws in the dynamic compression unit section for compression.
  • The shaft holes accept 3.5 mm locking screws in the threaded portion or 3.5 mm cortical screws or 4 mm cancellous screws in the compression portion.
  • 3.5 mm Locking Plate Metaphyseal allow implant placement to address the individual fracture pattern.
  • Limited-contact surface reduces bone-to-plate contact and helps to preserve the periosteal blood supply.
  • Choice of different lengths of plate eliminates the need to cut plates.
  • Available in both Titanium and Stainless steel.
  • locking plate increases construct stability, decreases risk of screw back-out and subsequent loss of reduction. It also reduces the need for precise anatomic plate contouring and minimizes the risk of stripped screw holes.
  • A complete Instruments Set is available for 3.5 mm Locking Plate Metaphyseal. General Instruments are available for this plate such as Plate Bending Press, Plate Holding Forceps, Plate Bending Pliers, Bone Holding Forceps, Bone Elevators, Bone Cutter, Bone Nibbler, Depth Gauge, Sleeve, Screw Driver, Trocar Sleeve etc.

3.5 mm Locking Plate Metaphyseal Uses

  • 3.5 mm Locking Plate Metaphyseal are designed to be used for the treatment of smaller bones particularly on Forearms and Humerus.
  • Low contact plate design allows smooth contour of plate to bone and limits Vascular Trauma to the bone.

3.5 mm Locking Plate Metaphyseal Contraindications

Contraindications may be qualified or total, and need to be taken into consideration when evaluating the prognosis in each case. Alternative management techniques may need to be considered under the following conditions:

  • Acute or chronic infections, either local or systemic.
  • Local or systemic accurate or chronic inflammation.
  • Serve muscular, nervous or vascular disease endangering the affected area.
  • Defective bone structures, which would impede adequate anchoring of the implant.
  • All associated diseases which could endanger the function and success of the implant.

Preoperative Planning for 3.5 mm Locking Plate Metaphyseal

The operating planning is carried out following a thorough clinical evaluation of the patient, Also, x-rays must be taken to allow a clear indication of the bony anatomy and associated deformities. At the time of the operation, the corresponding implantation instruments in addition to a complete set of 3.5 mm Locking Compression Plates must be available.

The clinician should discuss with the patient the possible risks and complications associated with the use of 3.5 mm Locking Plate Metaphyseal. It is important to determine pre-operatively whether the patient is allergic to any of the implant materials. Also, the patient needs to be informed that the performance of the device cannot be guaranteed as complications can affect the life expectancy of the device.

3.5 mm Locking Plate Metaphyseal Precautions

  • Confirm functionality of instruments and check for wear during reprocessing. Replace worn or damaged instruments prior to use.
  • It is recommended to use the instruments identified for this screw.
  • Handle devices with care and dispose worn bone cutting instruments in a sharps container.
  • Always irrigate and apply suction for removal of debris potentially generated during implantation or removal.

3.5 mm Locking Plate Metaphyseal Warnings

  • 3.5 mm Locking Plate Metaphyseal can break during use (when subjected to excessive forces). While the surgeon must make the final decision on removal of the broken part based on associated risk in doing so, we recommend that whenever possible and practical for the individual patient, the broken part should be removed. Be aware that implants are not as strong as native bone. Implants subjected to substantial loads may fail.
  • Instruments, screws and cut plates may have sharp edges or moving joints that may pinch or tear user’s glove or skin.
  • Take care to remove all fragments that are not fixated during the surgery.
  • While the surgeon must make the final decision on implant removal, we recommend that whenever possible and practical for the individual patient, fixation devices should be removed once their service as an aid to healing is accomplished. Implant removal should be followed by adequate post-operative management to avoid refracture.

3.5 mm Locking Plate Metaphyseal General Adverse Events

As with all major surgical procedures, risks, side effects and adverse events can occur. While many possible reactions may occur, some of the most common include: Problems resulting from anesthesia and patient positioning (e.g. nausea, vomiting, dental injuries, neurological impairments, etc.), thrombosis, embolism, infection, nerve and/or tooth root damage or injury of other critical structures including blood vessels, excessive bleeding, damage to soft tissues incl. swelling, abnormal scar formation, functional impairment of the musculoskeletal system, pain, discomfort or abnormal sensation due to the presence of the device, allergy or hypersensitivity reactions, side effects associated with hardware prominence, loosening, bending, or breakage of the device, mal-union, non-union or delayed union which may lead to breakage of the implant, reoperation.

The post Locking Plate Metaphyseal 3.5mm first appeared on Archoverseas.

]]>
Locking Plate Posterolateral Distal Fibula Plate 2.7/3.5mm, Right/Left https://archoverseas.com/product/locking-plate-posterolateral-distal-fibula-plate-2-7-3-5mm-right-left-2/?utm_source=rss&utm_medium=rss&utm_campaign=locking-plate-posterolateral-distal-fibula-plate-2-7-3-5mm-right-left-2 Sat, 22 Feb 2025 07:05:45 +0000 https://archoverseas.com/?post_type=product&p=18768 Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP679803 LCP679804 LCP679805 LCP679806 LCP679807 LCP679809 LCP679811 PDFP-003R PDFP-004R PDFP-005R PDFP-006R PDFP-007R PDFP-009R PDFP-011R Right Right Right Right Right Right Right 3H 4H 5H 6H 7H 9H 11H LCP679703 LCP679704 LCP679705 LCP679706 LCP679707 LCP679709 LCP679711 PDFP-003L PDFP-004L PDFP-005L PDFP-006L […]

The post Locking Plate Posterolateral Distal Fibula Plate 2.7/3.5mm, Right/Left first appeared on Archoverseas.

]]>
Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP679803

LCP679804

LCP679805

LCP679806

LCP679807

LCP679809

LCP679811 PDFP-003R

PDFP-004R

PDFP-005R

PDFP-006R

PDFP-007R

PDFP-009R

PDFP-011R Right

Right

Right

Right

Right

Right

Right 3H

4H

5H

6H

7H

9H

11H LCP679703

LCP679704

LCP679705

LCP679706

LCP679707

LCP679709

LCP679711 PDFP-003L

PDFP-004L

PDFP-005L

PDFP-006L

PDFP-007L

PDFP-009L

PDFP-011L Left

Left

Left

Left

Left

Left

Left 3H

4H

5H

6H

7H

9H

11H

The post Locking Plate Posterolateral Distal Fibula Plate 2.7/3.5mm, Right/Left first appeared on Archoverseas.

]]>
Locking Plate Anatomical Distal Tibia Plate For Fibula 3.5mm, Right/Left https://archoverseas.com/product/locking-plate-anatomical-distal-tibia-plate-for-fibula-3-5mm-right-left-2/?utm_source=rss&utm_medium=rss&utm_campaign=locking-plate-anatomical-distal-tibia-plate-for-fibula-3-5mm-right-left-2 Sat, 22 Feb 2025 07:05:45 +0000 https://archoverseas.com/?post_type=product&p=18769 Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP679305 LCP679307 LCP679309 LCP679311 LCP679313 AT-005R AT-007R AT-009R AT-011R AT-013R Right Right Right Right Right 5H 7H 9H 11H 13H LCP679405 LCP679407 LCP679409 LCP679411 LCP679413 AT-005L AT-007L AT-009L AT-011L AT-013L Left Left Left Left Left 5H 7H 9H 11H […]

The post Locking Plate Anatomical Distal Tibia Plate For Fibula 3.5mm, Right/Left first appeared on Archoverseas.

]]>
Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP679305

LCP679307

LCP679309

LCP679311

LCP679313 AT-005R

AT-007R

AT-009R

AT-011R

AT-013R Right

Right

Right

Right

Right 5H

7H

9H

11H

13H LCP679405

LCP679407

LCP679409

LCP679411

LCP679413 AT-005L

AT-007L

AT-009L

AT-011L

AT-013L Left

Left

Left

Left

Left 5H

7H

9H

11H

13H

The post Locking Plate Anatomical Distal Tibia Plate For Fibula 3.5mm, Right/Left first appeared on Archoverseas.

]]>
Locking Plate Distal Fibula Lateral 2.7/3.5mm, Right/Left https://archoverseas.com/product/locking-plate-distal-fibula-lateral-2-7-3-5mm-right-left-2/?utm_source=rss&utm_medium=rss&utm_campaign=locking-plate-distal-fibula-lateral-2-7-3-5mm-right-left-2 Sat, 22 Feb 2025 07:05:44 +0000 https://archoverseas.com/?post_type=product&p=18767 Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP679603 LCP679604 LCP679605 LCP679606 LCP679607 LCP679609 LCP679611 LDFP-003R LDFP-004R LDFP-005R LDFP-006R LDFP-007R LDFP-009R LDFP-011R Right Right Right Right Right Right Right 3H 4H 5H 6H 7H 9H 11H LCP679503 LCP679504 LCP679505 LCP679506 LCP679507 LCP679509 LCP679511 LDFP-003L LDFP-004L LDFP-005L LDFP-006L […]

The post Locking Plate Distal Fibula Lateral 2.7/3.5mm, Right/Left first appeared on Archoverseas.

]]>
Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP679603

LCP679604

LCP679605

LCP679606

LCP679607

LCP679609

LCP679611 LDFP-003R

LDFP-004R

LDFP-005R

LDFP-006R

LDFP-007R

LDFP-009R

LDFP-011R Right

Right

Right

Right

Right

Right

Right 3H

4H

5H

6H

7H

9H

11H LCP679503

LCP679504

LCP679505

LCP679506

LCP679507

LCP679509

LCP679511 LDFP-003L

LDFP-004L

LDFP-005L

LDFP-006L

LDFP-007L

LDFP-009L

LDFP-011L Left

Left

Left

Left

Left

Left

Left 3H

4H

5H

6H

7H

9H

11H

2.7/3.5 mm Locking Plate Distal Fibula Lateral, Right/Left Specification

  • Plates available holes are 3, 4, 5, 6, 7, 9 and 11.
  • Plates available for Left and Right both direction
  • Plate has combi holes and round holes. Combi holes allow fixation with locking screws in the threaded section and cortex screws in the dynamic compression unit section for compression.
  • The shaft holes accept 3.5 mm locking screws in the threaded portion or 3.5 mm cortical screws or 4 mm cancellous screws in the compression portion. Distal locking holes in plate head accept 2.7 mm locking screws.
  • 2.7/3.5 mm Locking Plate Distal Fibula Lateral, Right/Left allow implant placement to address the individual fracture pattern.
  • Coaxial Holes in plate head have recess to minimize screw prominence to create a low-profile construct.
  • Four K-wire holes in the head of the lateral plate accept 2 mm K-wires.
  • Limited-contact surface reduces bone-to-plate contact and helps to preserve the periosteal blood supply.
  • Choice of different lengths of plate eliminates the need to cut plates.
  • Pre-contoured plate to match anatomical shape.
  • Available in both Titanium and Stainless steel.
  • locking plate increases construct stability, decreases risk of screw back-out and subsequent loss of reduction. It also reduces the need for precise anatomic plate contouring and minimizes the risk of stripped screw holes.
  • A complete Instruments Set is available for 2.7/3.5 mm Locking Plate Distal Fibula Lateral, Right/Left. General Instruments are available for this plate such as Plate Bending Press, Plate Holding Forceps, Plate Bending Pliers, Bone Holding Forceps, Bone Elevators, Bone Cutter, Bone Nibbler, Depth Gauge, Sleeve, Screw Driver, Trocar Sleeve etc.

2.7/3.5 mm Locking Plate Distal Fibula Lateral, Right/Left Uses

2.7/3.5 mm Locking Plate Distal Fibula Lateral, Right/Left are indicated for fractures, osteotomies, and nonunions of the metaphyseal and diaphyseal region of the distal fibula, especially in osteopenic bone.

2.7/3.5 mm Locking Plate Distal Fibula Lateral, Right/Left Contraindications

Contraindications may be qualified or total, and need to be taken into consideration when evaluating the prognosis in each case. Alternative management techniques may need to be considered under the following conditions:

  • Acute or chronic infections, either local or systemic.
  • Local or systemic accurate or chronic inflammation.
  • Serve muscular, nervous or vascular disease endangering the affected area.
  • Defective bone structures, which would impede adequate anchoring of the implant.
  • All associated diseases which could endanger the function and success of the implant.

Warnings and Precautionary for 2.7/3.5 mm Locking Plate Distal Fibula Lateral, Right/Left

Before using 2.7/3.5 mm Locking Plate Distal Fibula Lateral, Right/Left, the surgeon and ancillary staff should study the safety information in these instructions, as well as any product-specific information in the product description, surgical procedures and/or brochures.

Plates are made from medical grade materials and are designed, constructed and produced with utmost care. These quality assure best working results provided they are used in the proper manner. Therefore, the following instructions for use and safety recommendations must be observed.

Improper use of Plates can lead to damage to the tissue, premature wear, destruction of the instruments and injury to the operator, patients or other persons.

It is vital for the operating surgeon to take an active role in the medical management of their patients. The surgeon should thoroughly understand all aspects of the surgical procedure and instruments including their limitations. Care in appropriate selection and proper use of surgical instruments is the responsibility of the surgeon and the surgical team. Adequate surgical training should be completed before use of this Plates.

Factors which could impair the success of the operation:

  • Allergies to implanted materials.
  • Localized bone tumours.
  • Osteoporosis or osteomalacia.
  • System disease and metabolic disturbances.
  • Alcohol and drug abuse.
  • Physical activities involving excessive shocks, whereby the implant is exposed to blows and/or excessive loading.
  • Patients who are mentally unable to understand and comply with the doctor’s instructions.
  • Poor general health.

Possible Adverse Effects

The following adverse effects are the most common resulting from implantation:

  • Loosening of the 2.7/3.5 mm Locking Plate Distal Fibula Lateral, Right/Left, which may result from cyclic loading of the fixation site and/or tissue reaction of the implant.
  • Early and late infection.
  • Further bone fracture resulting from unusual stress or weakened bone substance.
  • Temporary or chronic neural damage resulting from pressure or hematomata.
  • Wound hematomas and delayed wound healing.
  • Vascular disease including venal thrombosis, pulmonary embolism and cardiac arrest.
  • Heterotopic ossification.
  • Pain and discomfort due to presence of the Implants.
  • Mechanical failure of the implant, including bending, loosening or breakage.
  • Migration of implant resulting in injury.

Preoperative Planning for 2.7/3.5 mm Locking Plate Distal Fibula Lateral, Right/Left

The operating planning is carried out following a thorough clinical evaluation of the patient, Also, x-rays must be taken to allow a clear indication of the bony anatomy and associated deformities. At the time of the operation, the corresponding implantation instruments in addition to a complete set of 2.7/3.5 mm Locking Plate Distal Fibula Lateral, Right/Left must be available.

The clinician should discuss with the patient the possible risks and complications associated with the use of Implants. It is important to determine pre-operatively whether the patient is allergic to any of the implant materials. Also, the patient needs to be informed that the performance of the device cannot be guaranteed as complications can affect the life expectancy of the device.

2.7/3.5 mm Locking Plate Distal Fibula Lateral, Right/Left Precautions

  • Confirm functionality of instruments and check for wear during reprocessing. Replace worn or damaged instruments prior to use.
  • It is recommended to use the instruments identified for this screw.
  • Handle devices with care and dispose worn bone cutting instruments in a sharps container.
  • Always irrigate and apply suction for removal of debris potentially generated during implantation or removal.

2.7/3.5 mm Locking Plate Distal Fibula Lateral, Right/Left Warnings

  • 2.7/3.5 mm Locking Plate Distal Fibula Lateral, Right/Left can break during use (when subjected to excessive forces). While the surgeon must make the final decision on removal of the broken part based on associated risk in doing so, we recommend that whenever possible and practical for the individual patient, the broken part should be removed. Be aware that implants are not as strong as native bone. Implants subjected to substantial loads may fail.
  • Instruments, screws and cut plates may have sharp edges or moving joints that may pinch or tear user’s glove or skin.
  • Take care to remove all fragments that are not fixated during the surgery.
  • While the surgeon must make the final decision on implant removal, we recommend that whenever possible and practical for the individual patient, fixation devices should be removed once their service as an aid to healing is accomplished. Implant removal should be followed by adequate post-operative management to avoid refracture.

2.7/3.5 mm Locking Plate Distal Fibula Lateral, Right/Left General Adverse Events

As with all major surgical procedures, risks, side effects and adverse events can occur. While many possible reactions may occur, some of the most common include: Problems resulting from anesthesia and patient positioning (e.g. nausea, vomiting, dental injuries, neurological impairments, etc.), thrombosis, embolism, infection, nerve and/or tooth root damage or injury of other critical structures including blood vessels, excessive bleeding, damage to soft tissues incl. swelling, abnormal scar formation, functional impairment of the musculoskeletal system, pain, discomfort or abnormal sensation due to the presence of the device, allergy or hypersensitivity reactions, side effects associated with hardware prominence, loosening, bending, or breakage of the device, mal-union, non-union or delayed union which may lead to breakage of the implant, reoperation.

The post Locking Plate Distal Fibula Lateral 2.7/3.5mm, Right/Left first appeared on Archoverseas.

]]>
Locking Plate Anatomical Distal Tibia 3.5mm, Right/Left https://archoverseas.com/product/locking-plate-anatomical-distal-tibia-3-5mm-right-left-2/?utm_source=rss&utm_medium=rss&utm_campaign=locking-plate-anatomical-distal-tibia-3-5mm-right-left-2 Sat, 22 Feb 2025 07:05:43 +0000 https://archoverseas.com/?post_type=product&p=18764 Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP677505 LCP677507 LCP677509 LCP677511 LCP677513 ADT-005R ADT-007R ADT-009R ADT-011R ADT-013R Right Right Right Right Right 5H 7H 9H 11H 13H LCP677605 LCP677607 LCP677609 LCP677611 LCP677613 ADT-005L ADT-007L ADT-009L ADT-011L ADT-013L Left Left Left Left Left 5H 7H 9H 11H […]

The post Locking Plate Anatomical Distal Tibia 3.5mm, Right/Left first appeared on Archoverseas.

]]>
Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP677505

LCP677507

LCP677509

LCP677511

LCP677513 ADT-005R

ADT-007R

ADT-009R

ADT-011R

ADT-013R Right

Right

Right

Right

Right 5H

7H

9H

11H

13H LCP677605

LCP677607

LCP677609

LCP677611

LCP677613 ADT-005L

ADT-007L

ADT-009L

ADT-011L

ADT-013L Left

Left

Left

Left

Left 5H

7H

9H

11H

13H

The post Locking Plate Anatomical Distal Tibia 3.5mm, Right/Left first appeared on Archoverseas.

]]>
Locking Plate Pilon 3.5mm https://archoverseas.com/product/locking-plate-pilon-3-5mm-2/?utm_source=rss&utm_medium=rss&utm_campaign=locking-plate-pilon-3-5mm-2 Sat, 22 Feb 2025 07:05:43 +0000 https://archoverseas.com/?post_type=product&p=18765 Ref. No. Ti Ref. No. SS Size LCP669007 LCP669009 BS-007 BS-009 7H 9H 3.5 mm Locking Plate Pilon Specification Plates available holes are 7 and 9. Plate has combi holes and round holes. Combi holes allow fixation with locking screws in the threaded section and cortex screws in the dynamic compression unit section for compression. The […]

The post Locking Plate Pilon 3.5mm first appeared on Archoverseas.

]]>
Ref. No. Ti Ref. No. SS Size LCP669007

LCP669009 BS-007

BS-009 7H

9H

3.5 mm Locking Plate Pilon Specification

  • Plates available holes are 7 and 9.
  • Plate has combi holes and round holes. Combi holes allow fixation with locking screws in the threaded section and cortex screws in the dynamic compression unit section for compression.
  • The shaft holes accept 3.5 mm locking screws in the threaded portion or 3.5 mm cortical screws or 4 mm cancellous screws in the compression portion. Distal locking holes in plate head accept 3.5 mm locking screws or 4 mm Cancellous screws.
  • Can be cut and contoured for anatomic fit on left or right distal tibia.
  • May be placed on the anterior, medial, anteromedial, or anterolateral distal tibia.
  • Locking screws engaged in the plate create a fixed-angle construct that improves fixation in osteopenic bone and multifragment fractures.
  • The distal portion and arms may be contoured or holes may be removed as necessary.
  • 3.5 mm Locking Plate Pilon allow implant placement to address the individual fracture pattern.
  • Choice of different lengths of plate eliminates the need to cut plates.
  • Pre-contoured plate to match anatomical shape.
  • Available in both Titanium and Stainless steel.
  • locking plate increases construct stability, decreases risk of screw back-out and subsequent loss of reduction. It also reduces the need for precise anatomic plate contouring and minimizes the risk of stripped screw holes.
  • A complete Instruments Set is available for 3.5 mm Locking Plate Pilon. General Instruments are available for this plate such as Plate Bending Press, Plate Holding Forceps, Plate Bending Pliers, Bone Holding Forceps, Bone Elevators, Bone Cutter, Bone Nibbler, Depth Gauge, Sleeve, Screw Driver, Trocar Sleeve etc.

3.5 mm Locking Plate Pilon Uses

3.5 mm Locking Plate Pilon are indicated for extra-articular and intra-articular fractures and osteotomies of the distal tibia.

3.5 mm Locking Plate Pilon Contraindications

Contraindications may be qualified or total, and need to be taken into consideration when evaluating the prognosis in each case. Alternative management techniques may need to be considered under the following conditions:

  • Acute or chronic infections, either local or systemic.
  • Local or systemic accurate or chronic inflammation.
  • Serve muscular, nervous or vascular disease endangering the affected area.
  • Defective bone structures, which would impede adequate anchoring of the implant.
  • All associated diseases which could endanger the function and success of the implant.

Warnings and Precautionary for 3.5 mm Locking Plate Pilon

Before using 3.5 mm Locking Plate Pilon, the surgeon and ancillary staff should study the safety information in these instructions, as well as any product-specific information in the product description, surgical procedures and/or brochures.

Plates are made from medical grade materials and are designed, constructed and produced with utmost care. These quality assure best working results provided they are used in the proper manner. Therefore, the following instructions for use and safety recommendations must be observed.

Improper use of Plates can lead to damage to the tissue, premature wear, destruction of the instruments and injury to the operator, patients or other persons.

It is vital for the operating surgeon to take an active role in the medical management of their patients. The surgeon should thoroughly understand all aspects of the surgical procedure and instruments including their limitations. Care in appropriate selection and proper use of surgical instruments is the responsibility of the surgeon and the surgical team. Adequate surgical training should be completed before use of 3.5 mm Locking Plate Pilon.

Factors which could impair the success of the operation :

  • Allergies to implanted materials.
  • Localized bone tumours.
  • Osteoporosis or osteomalacia.
  • System disease and metabolic disturbances.
  • Alcohol and drug abuse.
  • Physical activities involving excessive shocks, whereby the implant is exposed to blows and/or excessive loading.
  • Patients who are mentally unable to understand and comply with the doctor’s instructions.
  • Poor general health.

Possible Adverse Effects

The following adverse effects are the most common resulting from implantation :

  • Loosening of the 3.5 mm Locking Plate Pilon, which may result from cyclic loading of the fixation site and/or tissue reaction of the implant.
  • Early and late infection.
  • Further bone fracture resulting from unusual stress or weakened bone substance.
  • Temporary or chronic neural damage resulting from pressure or hematomata.
  • Wound hematomas and delayed wound healing.
  • Vascular disease including venal thrombosis, pulmonary embolism and cardiac arrest.
  • Heterotopic ossification.
  • Pain and discomfort due to presence of the Implants.
  • Mechanical failure of the implant, including bending, loosening or breakage.
  • Migration of implant resulting in injury.

Preoperative Planning for 3.5 mm Locking Plate Pilon

The operating planning is carried out following a thorough clinical evaluation of the patient, Also, x-rays must be taken to allow a clear indication of the bony anatomy and associated deformities. At the time of the operation, the corresponding implantation instruments in addition to a complete set of 3.5 mm Locking Plate Pilon must be available.

The clinician should discuss with the patient the possible risks and complications associated with the use of 3.5 mm Locking Plate Pilon. It is important to determine pre-operatively whether the patient is allergic to any of the implant materials. Also, the patient needs to be informed that the performance of the device cannot be guaranteed as complications can affect the life expectancy of the device.

3.5 mm Locking Plate Pilon Precautions

  • Confirm functionality of instruments and check for wear during reprocessing. Replace worn or damaged instruments prior to use.
  • It is recommended to use the instruments identified for this screw.
  • Handle devices with care and dispose worn bone cutting instruments in a sharps container.
  • Always irrigate and apply suction for removal of debris potentially generated during implantation or removal.

3.5 mm Locking Plate Pilon Warnings

  • 3.5 mm Locking Plate Pilon can break during use (when subjected to excessive forces). While the surgeon must make the final decision on removal of the broken part based on associated risk in doing so, we recommend that whenever possible and practical for the individual patient, the broken part should be removed. Be aware that implants are not as strong as native bone. Implants subjected to substantial loads may fail.
  • Instruments, screws and cut plates may have sharp edges or moving joints that may pinch or tear user’s glove or skin.
  • Take care to remove all fragments that are not fixated during the surgery.
  • While the surgeon must make the final decision on implant removal, we recommend that whenever possible and practical for the individual patient, fixation devices should be removed once their service as an aid to healing is accomplished. Implant removal should be followed by adequate post-operative management to avoid refracture.

3.5 mm Locking Pilon Plates General Adverse Events

As with all major surgical procedures, risks, side effects and adverse events can occur. While many possible reactions may occur, some of the most common include: Problems resulting from anesthesia and patient positioning (e.g. nausea, vomiting, dental injuries, neurological impairments, etc.), thrombosis, embolism, infection, nerve and/or tooth root damage or injury of other critical structures including blood vessels, excessive bleeding, damage to soft tissues incl. swelling, abnormal scar formation, functional impairment of the musculoskeletal system, pain, discomfort or abnormal sensation due to the presence of the device, allergy or hypersensitivity reactions, side effects associated with hardware prominence, loosening, bending, or breakage of the device, mal-union, non-union or delayed union which may lead to breakage of the implant, reoperation.

The post Locking Plate Pilon 3.5mm first appeared on Archoverseas.

]]>
Locking Plate Fibula Distal Lateral 3.5mm https://archoverseas.com/product/locking-plate-fibula-distal-lateral-3-5mm-2/?utm_source=rss&utm_medium=rss&utm_campaign=locking-plate-fibula-distal-lateral-3-5mm-2 Sat, 22 Feb 2025 07:05:43 +0000 https://archoverseas.com/?post_type=product&p=18766 Ref. No. Ti Ref. No. SS Size LCP235005 LCP235006 LCP235007 LCP235008 LCP235009 LCP235010 LCP235011 LCP235012 LCP235013 LCP235014 FD-005 FD-006 FD-007 FD-008 FD-009 FD-010 FD-011 FD-012 FD-013 FD-014 5H 6H 7H 8H 9H 10H 11H 12H 13H 14H

The post Locking Plate Fibula Distal Lateral 3.5mm first appeared on Archoverseas.

]]>
Ref. No. Ti Ref. No. SS Size LCP235005

LCP235006

LCP235007

LCP235008

LCP235009

LCP235010

LCP235011

LCP235012

LCP235013

LCP235014 FD-005

FD-006

FD-007

FD-008

FD-009

FD-010

FD-011

FD-012

FD-013

FD-014 5H

6H

7H

8H

9H

10H

11H

12H

13H

14H

The post Locking Plate Fibula Distal Lateral 3.5mm first appeared on Archoverseas.

]]>
Locking Plate Distal Tibia 3.5mm, Right/Left https://archoverseas.com/product/locking-plate-distal-tibia-3-5mm-right-left-4/?utm_source=rss&utm_medium=rss&utm_campaign=locking-plate-distal-tibia-3-5mm-right-left-4 Sat, 22 Feb 2025 07:05:42 +0000 https://archoverseas.com/?post_type=product&p=18763 Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP668405 LCP668407 LCP668409 LCP668411 LCP668413 LCP668415 BW-005R BW-007R BW-009R BW-011R BW-013R BW-015R Right Right Right Right Right Right 5H 7H 9H 11H 13H 15H LCP668505 LCP668507 LCP668509 LCP668511 LCP668513 LCP668515 BW-005L BW-007L BW-009L BW-011L BW-013L BW-015L Left Left Left […]

The post Locking Plate Distal Tibia 3.5mm, Right/Left first appeared on Archoverseas.

]]>
Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP668405

LCP668407

LCP668409

LCP668411

LCP668413

LCP668415 BW-005R

BW-007R

BW-009R

BW-011R

BW-013R

BW-015R Right

Right

Right

Right

Right

Right 5H

7H

9H

11H

13H

15H LCP668505

LCP668507

LCP668509

LCP668511

LCP668513

LCP668515 BW-005L

BW-007L

BW-009L

BW-011L

BW-013L

BW-015L Left

Left

Left

Left

Left

Left 5H

7H

9H

11H

13H

15H

The post Locking Plate Distal Tibia 3.5mm, Right/Left first appeared on Archoverseas.

]]>
Locking Plate Anatomical Proximal Tibia 3.5mm, Right/Left https://archoverseas.com/product/locking-plate-anatomical-proximal-tibia-3-5mm-right-left-2/?utm_source=rss&utm_medium=rss&utm_campaign=locking-plate-anatomical-proximal-tibia-3-5mm-right-left-2 Sat, 22 Feb 2025 07:05:41 +0000 https://archoverseas.com/?post_type=product&p=18760 Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP677705 LCP677707 LCP677709 LCP677711 LCP677713 APT-005R APT-007R APT-009R APT-011R APT-013R Right Right Right Right Right 5H 7H 9H 11H 13H LCP677805 LCP677807 LCP677809 LCP677811 LCP677813 APT-005L APT-007L APT-009L APT-011L APT-013L Left Left Left Left Left 5H 7H 9H 11H […]

The post Locking Plate Anatomical Proximal Tibia 3.5mm, Right/Left first appeared on Archoverseas.

]]>
Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP677705

LCP677707

LCP677709

LCP677711

LCP677713 APT-005R

APT-007R

APT-009R

APT-011R

APT-013R Right

Right

Right

Right

Right 5H

7H

9H

11H

13H LCP677805

LCP677807

LCP677809

LCP677811

LCP677813 APT-005L

APT-007L

APT-009L

APT-011L

APT-013L Left

Left

Left

Left

Left 5H

7H

9H

11H

13H

The post Locking Plate Anatomical Proximal Tibia 3.5mm, Right/Left first appeared on Archoverseas.

]]>