2.4/2.7mm - Archoverseas https://archoverseas.com My WordPress Blog Sat, 22 Feb 2025 05:57:37 +0000 en-US hourly 1 https://wordpress.org/?v=6.8.2 https://archoverseas.com/wp-content/uploads/2024/11/cropped-Untitled-design-32x32.png 2.4/2.7mm - Archoverseas https://archoverseas.com 32 32 Locking Distal Dorsal Radius L-Plate 2.7mm Type-II, Right/Left https://archoverseas.com/product/locking-distal-dorsal-radius-l-plate-2-7mm-type-ii-right-left-4/?utm_source=rss&utm_medium=rss&utm_campaign=locking-distal-dorsal-radius-l-plate-2-7mm-type-ii-right-left-4 Fri, 21 Feb 2025 13:08:04 +0000 https://archoverseas.com/?post_type=product&p=18613 Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP558103 LCP558104 DDR-8103 DDR-8104 Right Right 3H 4H LCP558203 LCP558204 DDR-8203 DDR-8204 Left Left 3H 4H 2.7mm Locking Distal Dorsal Radius L-Plate Type-II, Right/Left Specification 2.7mm Locking Distal Dorsal Radius L-Plate Type-II, Right/Left two-plate technique offers a strong construct […]

The post Locking Distal Dorsal Radius L-Plate 2.7mm Type-II, Right/Left first appeared on Archoverseas.

]]>
Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP558103

LCP558104 DDR-8103

DDR-8104 Right

Right 3H

4H LCP558203

LCP558204 DDR-8203

DDR-8204 Left

Left 3H

4H

2.7mm Locking Distal Dorsal Radius L-Plate Type-II, Right/Left Specification

  • 2.7mm Locking Distal Dorsal Radius L-Plate Type-II, Right/Left two-plate technique offers a strong construct for complex distal radius fractures and avoids removal of Lister’s tubercle.
  • Straight plates are contoured to fit the radial column and have a notched tip that allows them to fit on the radial styloid, adjacent to a
    temporary K-wire fixation.
  • Locking Compression Plates (LCP) have Combi holes which allow locking screw fixation in the threaded section or compression in the non-threaded section of the hole.
  • Locking screws offer a fixed-angle construct to support the articular surface, reduce the need for bone graft, and obtain fixation in osteoporotic bone.
  • Low plate-and-screw profile minimizes potential for tendon and soft tissue irritation..
  • Rounded edges minimize potential for tendon adhesion.
  • Smaller plates and screws address fracture fragments individually, with less overall implant bulk.
  • Plates available holes are 3 and 4.
  • Plates available for Left and Right.
  • Plates available in Titanium.

2.7mm Locking Distal Dorsal Radius L-Plate Type-II, Right/Left uses

2.7mm Locking Distal Dorsal Radius L-Plate Type-II, Right/Left is used or fixation of complex intra and extra-articular fractures and osteotomies of the distal radius and other small bones.

The post Locking Distal Dorsal Radius L-Plate 2.7mm Type-II, Right/Left first appeared on Archoverseas.

]]>
Locking Plate Distal Lateral Radius 2.7mm https://archoverseas.com/product/locking-plate-distal-lateral-radius-2-7mm-4/?utm_source=rss&utm_medium=rss&utm_campaign=locking-plate-distal-lateral-radius-2-7mm-4 Fri, 21 Feb 2025 13:08:03 +0000 https://archoverseas.com/?post_type=product&p=18610 Ref. No. Ti Ref. No. SS Size LCP556005 LCP556006 DLR-6005 DLR-6006 5H 6H 2.7mm Locking Plate Distal Lateral Radius Specification 2.7mm Locking Plate Distal Lateral Radius two-plate technique offers a strong construct for complex distal radius fractures and avoids removal of Lister’s tubercle. Straight plates are contoured to fit the radial column and have a […]

The post Locking Plate Distal Lateral Radius 2.7mm first appeared on Archoverseas.

]]>
Ref. No. Ti Ref. No. SS Size LCP556005

LCP556006 DLR-6005

DLR-6006 5H

6H

2.7mm Locking Plate Distal Lateral Radius Specification

  • 2.7mm Locking Plate Distal Lateral Radius two-plate technique offers a strong construct for complex distal radius fractures and avoids removal of Lister’s tubercle.
  • Straight plates are contoured to fit the radial column and have a notched tip that allows them to fit on the radial styloid, adjacent to a
    temporary K-wire fixation.
  • Locking Compression Plates (LCP) have Combi holes which allow locking screw fixation in the threaded section or compression in the non-threaded section of the hole.
  • Locking screws offer a fixed-angle construct to support the articular surface, reduce the need for bone graft, and obtain fixation in osteoporotic bone.
  • Low plate-and-screw profile minimizes potential for tendon and soft tissue irritation..
  • Rounded edges minimize potential for tendon adhesion.
  • Smaller plates and screws address fracture fragments individually, with less overall implant bulk.
  • Plates available holes are 5 and 6.
  • Plates available in Titanium.

2.7mm Locking Locking Plate Distal Lateral Radius uses

2.7mm Locking Plate Distal Lateral Radius is used or fixation of complex intra and extra-articular fractures and osteotomies of the distal radius and other small bones.

The post Locking Plate Distal Lateral Radius 2.7mm first appeared on Archoverseas.

]]>
Locking Distal Dorsal Radius T-Plate 2.7mm https://archoverseas.com/product/locking-distal-dorsal-radius-t-plate-2-7mm-4/?utm_source=rss&utm_medium=rss&utm_campaign=locking-distal-dorsal-radius-t-plate-2-7mm-4 Fri, 21 Feb 2025 13:08:03 +0000 https://archoverseas.com/?post_type=product&p=18611 Ref. No. Ti Ref. No. SS Size LCP557003 LCP557004 DDR-7003 DDR-7004 3H 4H 2.7mm Locking Distal Dorsal Radius T-Plate Specification 2.7mm Locking Distal Dorsal Radius T-Plate two-plate technique offers a strong construct for complex distal radius fractures and avoids removal of Lister’s tubercle. Straight plates are contoured to fit the radial column and have a […]

The post Locking Distal Dorsal Radius T-Plate 2.7mm first appeared on Archoverseas.

]]>
Ref. No. Ti Ref. No. SS Size LCP557003

LCP557004 DDR-7003

DDR-7004 3H

4H

2.7mm Locking Distal Dorsal Radius T-Plate Specification

  • 2.7mm Locking Distal Dorsal Radius T-Plate two-plate technique offers a strong construct for complex distal radius fractures and avoids removal of Lister’s tubercle.
  • Straight plates are contoured to fit the radial column and have a notched tip that allows them to fit on the radial styloid, adjacent to a temporary K-wire fixation.
  • Locking Compression Plates (LCP) have Combi holes which allow locking screw fixation in the threaded section or compression in the non-threaded section of the hole.
  • Locking screws offer a fixed-angle construct to support the articular surface, reduce the need for bone graft, and obtain fixation in osteoporotic bone.
  • Low plate-and-screw profile minimizes potential for tendon and soft tissue irritation.
  • Rounded edges minimize potential for tendon adhesion.
  • Smaller plates and screws address fracture fragments individually, with less overall implant bulk.
  • Plates available holes are 3 and 4.
  • Plates available in Titanium.

2.7mm Locking Distal Dorsal Radius T-Plate uses

2.7mm Locking Distal Dorsal Radius T-Plate is used or fixation of complex intra and extra-articular fractures and osteotomies of the distal radius and other small bones.

The post Locking Distal Dorsal Radius T-Plate 2.7mm first appeared on Archoverseas.

]]>
Locking Distal Dorsal Radius L-Plate 2.7mm, Right/Left https://archoverseas.com/product/locking-distal-dorsal-radius-l-plate-2-7mm-right-left-4/?utm_source=rss&utm_medium=rss&utm_campaign=locking-distal-dorsal-radius-l-plate-2-7mm-right-left-4 Fri, 21 Feb 2025 13:08:03 +0000 https://archoverseas.com/?post_type=product&p=18612 Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP556103 LCP556104 DDR-6103 DDR-6104 Right Right 3H 4H LCP556203 LCP556204 DDR-6203 DDR-6204 Left Left 3H 4H 2.7mm Locking Distal Dorsal Radius L-Plate , Right/Left Specification 2.7mm Locking Distal Dorsal Radius L-Plate , Right/Left two-plate technique offers a strong construct […]

The post Locking Distal Dorsal Radius L-Plate 2.7mm, Right/Left first appeared on Archoverseas.

]]>
Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP556103

LCP556104 DDR-6103

DDR-6104 Right

Right 3H

4H LCP556203

LCP556204 DDR-6203

DDR-6204 Left

Left 3H

4H

2.7mm Locking Distal Dorsal Radius L-Plate , Right/Left Specification

  • 2.7mm Locking Distal Dorsal Radius L-Plate , Right/Left two-plate technique offers a strong construct for complex distal radius fractures and avoids removal of Lister’s tubercle.
  • Straight plates are contoured to fit the radial column and have a notched tip that allows them to fit on the radial styloid, adjacent to a
    temporary K-wire fixation.
  • Locking Compression Plates (LCP) have Combi holes which allow locking screw fixation in the threaded section or compression in the non-threaded section of the hole.
  • Locking screws offer a fixed-angle construct to support the articular surface, reduce the need for bone graft, and obtain fixation in osteoporotic bone.
  • Low plate-and-screw profile minimizes potential for tendon and soft tissue irritation..
  • Rounded edges minimize potential for tendon adhesion.
  • Smaller plates and screws address fracture fragments individually, with less overall implant bulk.
  • Plates available holes are 3 and 4.
  • Plates available for Left and Right.
  • Plates available in Titanium.

2.7mm Locking Distal Dorsal Radius L-Plate , Right/Left uses

2.7mm Locking Distal Dorsal Radius L-Plate , Right/Left is used or fixation of complex intra and extra-articular fractures and osteotomies of the distal radius and other small bones.

The post Locking Distal Dorsal Radius L-Plate 2.7mm, Right/Left first appeared on Archoverseas.

]]>
Locking Plate Extra-Articular Volar Distal Radius 2.4/2.7mm 5 Hole Head Type-II, Right/Left https://archoverseas.com/product/locking-plate-extra-articular-volar-distal-radius-2-4-2-7mm-5-hole-head-type-ii-right-left-4/?utm_source=rss&utm_medium=rss&utm_campaign=locking-plate-extra-articular-volar-distal-radius-2-4-2-7mm-5-hole-head-type-ii-right-left-4 Fri, 21 Feb 2025 13:08:02 +0000 https://archoverseas.com/?post_type=product&p=18608 Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP676503 LCP676504 LCP676505 VR-003R VR-004R VR-005R Right Right Right 3H 4H 5H LCP676603 LCP676604 LCP676605 VR-003L VR-004L VR-005L Left Left Left 3H 4H 5H 2.4/2.7mm Locking Plate Extra-Articular Volar Distal Radius 5 Hole Head Type-II, Right/Left Specification 2.4/2.7mm Locking Plate […]

The post Locking Plate Extra-Articular Volar Distal Radius 2.4/2.7mm 5 Hole Head Type-II, Right/Left first appeared on Archoverseas.

]]>
Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP676503

LCP676504

LCP676505 VR-003R

VR-004R

VR-005R Right

Right

Right 3H

4H

5H LCP676603

LCP676604

LCP676605 VR-003L

VR-004L

VR-005L Left

Left

Left 3H

4H

5H

2.4/2.7mm Locking Plate Extra-Articular Volar Distal Radius 5 Hole Head Type-II, Right/Left Specification

  • 2.4/2.7mm Locking Plate Extra-Articular Volar Distal Radius 5 Hole Head Type-II, Right/Left is precontoured with a complex bend designed to fit the volar surface of the distal radius. Juxta-articular plates may be used for more complex fractures. Placement is as distal as possible on the radius. The locking holes in the head of the plate are angled 5° proximal to the articular surface, to allow a more distal plate placement.
  • Straight plates are contoured to fit the radial column and have a notched tip that allows them to fit on the radial styloid, adjacent to a temporary K-wire fixation.
  • Locking Compression Plates (LCP) have Combi holes which allow locking screw fixation in the threaded section or compression in the non-threaded section of the hole.
  • Locking screws offer a fixed-angle construct to support the articular surface, reduce the need for bone graft, and obtain fixation in osteoporotic bone.
  • Undercuts on the bottom of the plate head facilitate contouring of the plate to match the anatomy of the distal radius and minimize the
    potential for soft tissue irritation.
  • Rounded edges minimize potential for tendon adhesion.
  • Smaller plates and screws address fracture fragments individually, with less overall implant bulk.
  • Plate available with 5 head holes and 3 and 5 shaft holes.
  • Plates available for Left and Right.
  • Plates available in Titanium.

2.4/2.7mm Locking Plate Extra-Articular Volar Distal Radius 5 Hole Head Type-II, Right/Left uses

2.4/2.7mm Locking Plate Extra-Articular Volar Distal Radius 5 Hole Head Type-II, Right/Left is used or fixation of complex intra and extra-articular fractures and osteotomies of the distal radius and other small bones.

The post Locking Plate Extra-Articular Volar Distal Radius 2.4/2.7mm 5 Hole Head Type-II, Right/Left first appeared on Archoverseas.

]]>
Locking Plate Extra-Articular Volar Distal Radius 2.4/2.7mm 5 Hole Head Type-III, Right/Left https://archoverseas.com/product/locking-plate-extra-articular-volar-distal-radius-2-4-2-7mm-5-hole-head-type-iii-right-left-4/?utm_source=rss&utm_medium=rss&utm_campaign=locking-plate-extra-articular-volar-distal-radius-2-4-2-7mm-5-hole-head-type-iii-right-left-4 Fri, 21 Feb 2025 13:08:02 +0000 https://archoverseas.com/?post_type=product&p=18609 Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP676703 LCP676704 LCP676705 VS-003L VS-004L VS-005L Right Right Right 3H 4H 5H LCP676803 LCP676804 LCP676805 VS-003R VS-004R VS-005R Left Left Left 3H 4H 5H 2.4/2.7mm Locking Plate Extra-Articular Volar Distal Radius 5 Hole Head Type-III, Right/Left Specification 2.4/2.7mm Locking Plate […]

The post Locking Plate Extra-Articular Volar Distal Radius 2.4/2.7mm 5 Hole Head Type-III, Right/Left first appeared on Archoverseas.

]]>
Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP676703

LCP676704

LCP676705 VS-003L

VS-004L

VS-005L Right

Right

Right 3H

4H

5H LCP676803

LCP676804

LCP676805 VS-003R

VS-004R

VS-005R Left

Left

Left 3H

4H

5H

2.4/2.7mm Locking Plate Extra-Articular Volar Distal Radius 5 Hole Head Type-III, Right/Left Specification

  • 2.4/2.7mm Locking Plate Extra-Articular Volar Distal Radius 5 Hole Head Type-III, Right/Left is precontoured with a complex bend designed to fit the volar surface of the distal radius. Juxta-articular plates may be used for more complex fractures. Placement is as distal as possible on the radius. The locking holes in the head of the plate are angled 5° proximal to the articular surface, to allow a more distal plate placement.
  • Straight plates are contoured to fit the radial column and have a notched tip that allows them to fit on the radial styloid, adjacent to a temporary K-wire fixation.
  • Locking Compression Plates (LCP) have Combi holes which allow locking screw fixation in the threaded section or compression in the non-threaded section of the hole.
  • Locking screws offer a fixed-angle construct to support the articular surface, reduce the need for bone graft, and obtain fixation in osteoporotic bone.
  • Undercuts on the bottom of the plate head facilitate contouring of the plate to match the anatomy of the distal radius and minimize the
    potential for soft tissue irritation.
  • Rounded edges minimize potential for tendon adhesion.
  • Smaller plates and screws address fracture fragments individually, with less overall implant bulk.
  • Plate available with 5 head holes and 3 and 5 shaft holes.
  • Plates available for Left and Right.
  • Plates available in Titanium.

2.4/2.7mm Locking Plate Extra-Articular Volar Distal Radius 5 Hole Head Type-III, Right/Left uses

2.4/2.7mm Locking Plate Extra-Articular Volar Distal Radius 5 Hole Head Type-III, Right/Left is used or fixation of complex intra and extra-articular fractures and osteotomies of the distal radius and other small bones.

The post Locking Plate Extra-Articular Volar Distal Radius 2.4/2.7mm 5 Hole Head Type-III, Right/Left first appeared on Archoverseas.

]]>
Locking Plate Extra-Articular Volar Distal Radius 2.4/2.7mm 5 Hole Head Type-I, Right/Left https://archoverseas.com/product/locking-plate-extra-articular-volar-distal-radius-2-4-2-7mm-5-hole-head-type-i-right-left-4/?utm_source=rss&utm_medium=rss&utm_campaign=locking-plate-extra-articular-volar-distal-radius-2-4-2-7mm-5-hole-head-type-i-right-left-4 Fri, 21 Feb 2025 13:08:01 +0000 https://archoverseas.com/?post_type=product&p=18607 Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP676303 LCP676304 LCP676305 VD-003R VD-004R VD-005R Right Right Right 3H 4H 5H LCP676403 LCP676404 LCP676405 VD-003L VD-004L VD-005L Left Left Left 3H 4H 5H 2.4/2.7mm Locking Plate Extra-Articular Volar Distal Radius 5 Hole Head Type-I, Right/Left Specification 2.4/2.7mm Locking Plate […]

The post Locking Plate Extra-Articular Volar Distal Radius 2.4/2.7mm 5 Hole Head Type-I, Right/Left first appeared on Archoverseas.

]]>
Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP676303

LCP676304

LCP676305 VD-003R

VD-004R

VD-005R Right

Right

Right 3H

4H

5H LCP676403

LCP676404

LCP676405 VD-003L

VD-004L

VD-005L Left

Left

Left 3H

4H

5H

2.4/2.7mm Locking Plate Extra-Articular Volar Distal Radius 5 Hole Head Type-I, Right/Left Specification

  • 2.4/2.7mm Locking Plate Extra-Articular Volar Distal Radius 5 Hole Head Type-I, Right/Left is precontoured for anatomic fit of the volar aspect of the distal radius, so that plate placement is away from the articular surface. Extra-articular volar distal radius plates can be used for simple intra or extra-articular fractures. Diverging screw angles secure the radial styloid and other distal fragments.
  • Straight plates are contoured to fit the radial column and have a notched tip that allows them to fit on the radial styloid, adjacent to a
    temporary K-wire fixation.
  • Locking Compression Plates (LCP) have Combi holes which allow locking screw fixation in the threaded section or compression in the non-threaded section of the hole.
  • Locking screws offer a fixed-angle construct to support the articular surface, reduce the need for bone graft, and obtain fixation in osteoporotic bone.
  • Low plate-and-screw profile minimizes potential for tendon and soft tissue irritation..
  • Rounded edges minimize potential for tendon adhesion.
  • Smaller plates and screws address fracture fragments individually, with less overall implant bulk.
  • Plates available holes are 3, 4 and 5.
  • Plates available for Left and Right.
  • Plates available in Titanium.

2.4/2.7mm Locking Plate Extra-Articular Volar Distal Radius 5 Hole Head Type-I, Right/Left uses

2.4/2.7mm Locking Plate Extra-Articular Volar Distal Radius 5 Hole Head Type-I, Right/Left is used or fixation of complex intra- and extra-articular fractures and osteotomies of the distal radius and other small bones.

The post Locking Plate Extra-Articular Volar Distal Radius 2.4/2.7mm 5 Hole Head Type-I, Right/Left first appeared on Archoverseas.

]]>
Locking Plate Proximal Radius 2.4/2.7mm (Locking Neck Plate For Radial Head) https://archoverseas.com/product/locking-plate-proximal-radius-2-4-2-7mm-locking-neck-plate-for-radial-head-4/?utm_source=rss&utm_medium=rss&utm_campaign=locking-plate-proximal-radius-2-4-2-7mm-locking-neck-plate-for-radial-head-4 Fri, 21 Feb 2025 13:08:00 +0000 https://archoverseas.com/?post_type=product&p=18604 Ref. No. Ti Ref. No. SS Size LCP730002 LCP730003 LCP730004 NHP-002 NHP-003 NHP-004 2H 3H 4H 2.4/2.7mm Locking Plate Proximal Radius (Locking Neck Plate For Radial Head) Specification Plates are precontoured for anatomical fit. Combi holes allow fixation with locking screws in the threaded section for angular stability, and cortex screws in the Dynamic Compression […]

The post Locking Plate Proximal Radius 2.4/2.7mm (Locking Neck Plate For Radial Head) first appeared on Archoverseas.

]]>
Ref. No. Ti Ref. No. SS Size LCP730002

LCP730003

LCP730004 NHP-002

NHP-003

NHP-004 2H

3H

4H

2.4/2.7mm Locking Plate Proximal Radius (Locking Neck Plate For Radial Head) Specification

  • Plates are precontoured for anatomical fit.
  • Combi holes allow fixation with locking screws in the threaded section for angular stability, and cortex screws in the Dynamic Compression Unit (DCU) section for distraction. A fixed-angle construct provides advantages in osteopenic bone or multifragment fractures, where traditional
    screw purchase is compromised.
  • The holes in the head of the plate accept 2.4mm locking screws and 2mm cortex screws.
  • The shaft holes accept 2.4mm locking screws in the threaded portion or 2.7mm cortex screws and 2.4mm cortex screws in the distraction portion.
  • Plates available holes are 2, 3 and 4
  • Plates available in Titanium.

2.4/2.7mm Locking Plate Proximal Radius (Locking Neck Plate For Radial Head) uses

2.4/2.7mm Locking Plate Proximal Radius (Locking Neck Plate For Radial Head) indicated for Extra-articular and intra-articular fractures of the proximal radius and multifragmented radial neck fractures.

The post Locking Plate Proximal Radius 2.4/2.7mm (Locking Neck Plate For Radial Head) first appeared on Archoverseas.

]]>
Locking Plate Volar Column Distal Radius 2.4/2.7mm 6 Hole Head, Right/Left https://archoverseas.com/product/locking-plate-volar-column-distal-radius-2-4-2-7mm-6-hole-head-right-left-4/?utm_source=rss&utm_medium=rss&utm_campaign=locking-plate-volar-column-distal-radius-2-4-2-7mm-6-hole-head-right-left-4 Fri, 21 Feb 2025 13:08:00 +0000 https://archoverseas.com/?post_type=product&p=18605 Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP691602 LCP691603 LCP691604 LCP691605 VC-002R VC-003R VC-004R VC-005R Right Right Right Right 2H 3H 4H 5H LCP691502 LCP691503 LCP691504 LCP691505 VC-002L VC-003L VC-004L VC-005L Left Left Left Left 2H 3H 4H 5H 2.4/2.7mm Locking Plate Volar Column Distal Radius […]

The post Locking Plate Volar Column Distal Radius 2.4/2.7mm 6 Hole Head, Right/Left first appeared on Archoverseas.

]]>
Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP691602

LCP691603

LCP691604

LCP691605 VC-002R

VC-003R

VC-004R

VC-005R Right

Right

Right

Right 2H

3H

4H

5H LCP691502

LCP691503

LCP691504

LCP691505 VC-002L

VC-003L

VC-004L

VC-005L Left

Left

Left

Left 2H

3H

4H

5H

2.4/2.7mm Locking Plate Volar Column Distal Radius 6 Hole Head, Right/Left Specification

  • 2.4/2.7mm Locking Plate Volar Column Distal Radius 6 Hole Head, Right/Left is contoured to fit the radial column and have a notched tip that allows them to fit on the radial styloid, adjacent to a temporary K-wire fixation.
  • Locking Compression Plates (LCP) have Combi holes which allow locking screw fixation in the threaded section or compression in the non-threaded section of the hole.
  • Locking screws offer a fixed-angle construct to support the articular surface, reduce the need for bone graft, and obtain fixation in osteoporotic bone.
  • Low plate-and-screw profile minimizes potential for tendon and soft tissue irritation..
  • Rounded edges minimize potential for tendon adhesion.
  • Smaller plates and screws address fracture fragments individually, with less overall implant bulk.
  • Plate available with 6 head holes and 2 shaft holes.
  • Plates available for Left and Right.
  • Plates available in Titanium.

2.4/2.7mm Locking Plate Volar Column Distal Radius 6 Hole Head, Right/Left uses

2.4/2.7mm Locking Plate Volar Column Distal Radius 6 Hole Head, Right/Left is used or fixation of complex intra- and extra-articular fractures and osteotomies of the distal radius and other small bones.

The post Locking Plate Volar Column Distal Radius 2.4/2.7mm 6 Hole Head, Right/Left first appeared on Archoverseas.

]]>
Locking Plate Extra-Articular Volar Distal Radius 2.4/2.7mm 4 Hole Head, Right/Left https://archoverseas.com/product/locking-plate-extra-articular-volar-distal-radius-2-4-2-7mm-4-hole-head-right-left-4/?utm_source=rss&utm_medium=rss&utm_campaign=locking-plate-extra-articular-volar-distal-radius-2-4-2-7mm-4-hole-head-right-left-4 Fri, 21 Feb 2025 13:08:00 +0000 https://archoverseas.com/?post_type=product&p=18606 Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP676103 LCP676104 LCP676105 VA-003R VA-004R VA-005R Right Right Right 3H 4H 5H LCP676203 LCP676204 LCP676205 VA-003L VA-004L VA-005L Left Left Left 3H 4H 5H 2.4/2.7mm Locking Plate Extra-Articular Volar Distal Radius 4 Hole Head, Right/Left Specification 2.4/2.7mm Locking Plate […]

The post Locking Plate Extra-Articular Volar Distal Radius 2.4/2.7mm 4 Hole Head, Right/Left first appeared on Archoverseas.

]]>
Ref. No. Ti Ref. No. SS Position Size Ref. No. Ti Ref. No. SS Position Size LCP676103

LCP676104

LCP676105 VA-003R

VA-004R

VA-005R Right

Right

Right 3H

4H

5H LCP676203

LCP676204

LCP676205 VA-003L

VA-004L

VA-005L Left

Left

Left 3H

4H

5H

2.4/2.7mm Locking Plate Extra-Articular Volar Distal Radius 4 Hole Head, Right/Left Specification

  • 2.4/2.7mm Locking Plate Extra-Articular Volar Distal Radius 4 Hole Head, Right/Left is precontoured for anatomic fit of the volar aspect of the distal radius, so that plate placement is away from the articular surface. Extra-articular volar distal radius plates can be used for simple intra or extra-articular fractures. Diverging screw angles secure the radial styloid and other distal fragments.
  • Straight plates are contoured to fit the radial column and have a notched tip that allows them to fit on the radial styloid, adjacent to a
    temporary K-wire fixation.
  • Locking Compression Plates (LCP) have Combi holes which allow locking screw fixation in the threaded section or compression in the non-threaded section of the hole.
  • Locking screws offer a fixed-angle construct to support the articular surface, reduce the need for bone graft, and obtain fixation in osteoporotic bone.
  • Low plate-and-screw profile minimizes potential for tendon and soft tissue irritation..
  • Rounded edges minimize potential for tendon adhesion.
  • Smaller plates and screws address fracture fragments individually, with less overall implant bulk.
  • Plates available holes are 3, 4 and 5.
  • Plates available for Left and Right.
  • Plates available in Titanium.

2.4/2.7mm Locking Plate Extra-Articular Volar Distal Radius 4 Hole Head, Right/Left uses

2.4/2.7mm Locking Plate Extra-Articular Volar Distal Radius 4 Hole Head, Right/Left is used or fixation of complex intra and extra-articular fractures and osteotomies of the distal radius and other small bones.

The post Locking Plate Extra-Articular Volar Distal Radius 2.4/2.7mm 4 Hole Head, Right/Left first appeared on Archoverseas.

]]>